eddyliner P®
Eddy Current Instruments for
Hardness Testing, Structure Testing , Material Properties Testing
Fully equipped eddy current instruments for
production quality control, preventive
multi-frequency method. Only GOOD parts required
for calibration
Tests for material mix and
structure variations In parts

Reasonably priced Eddy
current quality
control equipment
The eddyliner® P is an eddy current instrument
specifically designed for versatility in
production line testing for material mix, heat
treatment (hardness, case, depth, temper, etc.),
sinter density and structure differences.
The eddyliner® P’s principle of operation is
based on a multi-frequency test to provide a far
greater degree of reliability than single
frequency eddy current instruments. Operation is
supported by a full on-board computer to
simplify calibration and sort procedures.
Use of leading edge electronic techniques allows
extremely short testing times, even with
multi-frequency scanning. Opto-isolated
interfacing integrates the eddyliner® P into
automatic inspection and sort lines and
equipment.
The compact instrument is designed for
simplicity of operation. A “help” key (“Context
Sensitive Help”) is available to provide
assistance for each operating function.
Application versatility is an in-built feature
with a wide range of accessories available to
adapt the eddyliner® P to differing job
functions.
MULTI-FREQUENCY METHOD
During calibration, known reference parts are
tested over a broad frequency band (1:100 -
1:1000). Typical impedance curves develop which
are influenced by various metallurgical
characteristics (alloy, structure, etc.)
Subsequent sorting decisions on unknown parts
dictate that they must meet all and every
criteria in order to be accepted. Deviations are
automatically recognized and sorted. Test
reliability is significantly higher compared to
mono-frequency testing.
PRODUCTION PROGRAM
Permits calibration of the instrument with
“good” production parts only, at up to 8
different test frequencies. Operating procedures
from “Calibration” to “Sorting” are extremely
simple, with rapid segregation of “O.K.” and
“NOT O.K.” material at up to 8 different
frequencies.
OPERATION
All functions are displayed on the LCD.
Calibration and test procedures are simplified
by a built-in computer. Sequence guidance
provided by softkeys and help function. “Context
Sensitive Help” provides detailed information on
softkey functions and program steps.
INTERNAL DATA STORAGE
Up to 16 possible frequency band combinations
may be selected for calibration purposes. and 50
complete set-ups may be stored for future
access.
EXTERNAL DATA STORAGE
Permits storage of set-up parameters on external
“Memory Plug” (EEPROM) for transfer to other
eddyliner® P units, simply by plugging in the
Memory Plug at the front panel.
DOCUMENTATION
The eddyliner® P is equipped with a Centronics
interface for communication with external
printers to provide hardcopy printouts of the
test results.
RS232 / V24 INTERFACE
An RS232 / V24 interface permits communication
with separate main-frame computers to perform
statistical analysis (SPC) of accumulated data.
SORTING
The sorting decision is “O.K.” or “NOT O.K.”.
Test results are displayed by red or green sort
indicator lamps and audible signal as well as
graphically and numerically. After each test,
measured values are statistically evaluated in
numerical and percentage form.
OPTO INTERFACE
Permits input of external control signals and
transfer of sorting decisions to peripheral
accessories. For example, starting of
measurement by photoelectric cell, transfer of
sorting decision to gate mechanism, visual and
audible alarm signals.
TRANSDUCERS
Suitable coils and probes are available for most
applications. Standard transducers cover a wide
range of applications. Special coils and probes
can be developed for specific frequency ranges
and part dimensions.
CASING OPTIONS
The following optional accessories are available
for the eddyliner® P: Carrying handle with edge
protection for bench case; Lockable Plexiglas
front panel for bench case; 6 HU front panel for
integration into 19” rack; 6 HU steel rack,
protection IP54 (W x H x D: 600 x 330 x 450 mm).
TECHNICAL DATA
|
Teet frequency range |
: |
5 Hz – 300 KHz |
|
Measuring time |
: |
64 ms at 8 frequency (minimum) |
|
LCD display |
: |
125 X 70 mm, background lighting,
brightness and contrast adjustable |
|
Microprocessor |
: |
2 CPUs for highest test speed |
|
Memory |
: |
1 main memory, Li-battery backed
16
memories for frequency band
combinations 16 program memories. |
|
Interfaces |
: |
Opto-interface for control of “O.K.
NOT O.K". output Handshake Centronics
printer interface V 24/RS 232 |
|
Mains connection voltage |
: |
85V-245V Vac. 50/60 Hz |
|
Power requirement |
: |
50 VA |
|
Dimensions |
: |
L 262 X W 364 X H 147 mm (bench
case) |
|
Weight |
: |
6 kg |
| |
|
We reserve the right to alter or
amend technical data without prior
notice |
|
|
|
|
|
ibg NDT Systems - Designers and
manufacturers of state-of-the-art
NDT eddy current testers,
instruments, and systems for
automotive and
aerospace critical parts.
|
|