Structure Test with eddyvisor®
Preventive
Multi-Frequency Test with State-of-the-Art
µP-Technology
-
Only OK parts required
for calibration
-
Proven Preventive
Multi-Frequency Testing with 8 test
frequencies at each test location
-
32 test locations (each
with 8 tolerance fields) enable maximum
flexibility
-
Basic instrument
includes 2 coil channels (up to 32 as an
option)
-
Maximum stability of
results due to automatic calibration
-
Highest test reliability
due to PMFT and automatic calibration
-
High-speed testing
within milliseconds
-
15” touch screen for
easy and clear operation, with many useful
graphic options
-
USB2.0 and Ethernet
interfaces for easy data transfer to PC and printer and remote control, data storage to USB stick
-
Programmable access
levels for different responsibility levels
-
Desktop version (DS) and
the new two-part switch panel version (MS)
The eddy current test
instrument eddyvisor®
xS is designed for testing material mix, heat
treatment (hardness, case depth, temper, etc.),
sinter density and structure differences.
eddyvisor®
xS is specifically designed for versatility in
production lines or laboratory use and its
principle of operation is based on ibg’s
Preventive Multi-Frequency Testing (PMFT). Thus
it provides a far greater degree of reliability
than single frequency eddy current instruments.
The path from calibration of eddyvisor®
xS to start of testing is very short and simple.
The instrument is operated via a bright 15"
touch screen with ergonomically-designed input
format. Modem electronics enable extremely short
calculation and load time, i.e., microseconds.
eddyvisor®
xS is available in two different versions and
the basic model includes two independent test
channels. Up to 32 test locations may be stored.
Models with up to 16 or up to 32 test channels
are available. The
Preventive Multi-Frequency Method:
Only OK part are required for calibrating
eddyvisor®
xS. During calibration known reference parts are
tested over a broad frequency band (1:1000 up to
1:3000) with up to 8 frequencies. Subsequently a
typical material locus curve develops. Like a
fingerprint, it reflects the different
characteristics of material such as alloy,
structure from heat treatment and allowable
scattering of the known OK parts.
Due to very easy operation eddyvisor®
xS can quickly be brought into test mode.
Testing is also carried out with 8 frequencies.
OK decisions are only reached if all and every
criteria of the test part correspond to the
known data. Thus unexpected deviations are
recognized and sorted out. Test reliability is
significantly higher compared with
single-frequency testing.
After each test the measured values are
statistically updated with numerical and
percentage information. Furthermore the latest
300 test results are displayed as histogram and up to 500 are stored.
Date Security:
Up to 16 possible frequency band combinations
may be selected for calibration and testing with
eddyvisor®
xS. In addition, up to 200 test part types may
be internally stored and quickly called by means
of PLC or stored on an USB stick.
Documentation and data transfer:
For documentation and data transfer, eddyvisor®
xS is equipped with 3 USB 2.0 interfaces (2 of
them on front side) as well as an Ethernet
interface. An external printer may be connected
(Centronics or USB) for hard copies of test
results.
Opto-isolated interface:
An opto-isolated interface with 64 (option max.
128) in-and outputs is available for connection
of a PLC to control automatic systems.
Coils and probes:
Proven ibg standard and customized encircling
coils and probes are provided for all
applications (refer to separate data sheet).
Case options:
The eddyvisor®
xS is available as desktop version named
eddyvisor®
DS or as divided rack mount housing including
the operating unit eddyvisor®
HMI (Human Machine Interface) and the measuring
unit eddyvisor®
MS
TECHNICAL DATA
| Test
method |
:
|
Preventing Multi-Frequency Testing with
max. 8 test frequencies at up to 32 test
locations. |
| Coil
channels |
:
|
2,
option up to 32 channels |
| Test
frequency range |
:
|
5 Hz –
300 kHz, adjustable for each test
location |
| Test
time |
:
|
8
ms/frequency (min.) |
| Micro
processor |
:
|
several
high-performance processors for maximum
test speed. |
| Mains
voltage |
:
|
90…264
V AC, 47…63 Hz |
| Power
requirement |
:
|
120 VA |
| Dimensions |
: |
eddyvisor®
DS w 410mm x h 308mm x d 271mm
eddyvisor®
HMI w 410mm x h 308mm x d 96mm
eddyvisor®
MS w 410mm x h 308mm x d 175mm |
| |
:
|
wxhxd
483 mm x 190 mm x 370 mm |
| Weight |
:
|
13 kg |
(Subject to technical
changes without prior notice) |